Maintenance Guide

Southern Steel 1050 Gate Lock Maintenance

Normally, the Southern Steell 1050 gate lock should not require adjustments after being properly installed. Maintenance tips for all Southern Steel locks is provided in the General Maintenance Guidelines. Review these guidelines before attempting to trouble shoot the 1050.

Periodically check installation of lock and latch for loose mounting hardware.  Check control panel for proper light indication when gate is locked or unlocked. If proper light indication can not be achieved (and control panel checks good) remove the lock cover plate and adjust the limit switch actuator until correct indicator light illumination is attained.

Also, all internal moving parts, except the solenoid, should be lightly lubricated with a Teflon-based spray lubricant once every three month or as needed.

Do not over-lubricate lock Darts.